T1 - Alteration of the intaglio surface of lithium disilicate glass-ceramic
AU - Gorman, Catherine M.
AU - de Faoite, Daithi
AU - Flannery, David
AU - Ratajczak, Marta
AU - Kelly, Tomás
AU - Stanton, Kenneth T.
N1 - Publisher Copyright:
© 2019 Editorial Council for the Journal of Prosthetic Dentistry
PY - 2019/10
Y1 - 2019/10
N2 - Statement of problem: Clinical adjustment of a lithium disilicate glass-ceramic (LDGC) restoration may necessitate its return to the laboratory for additional firing. Evidence of how the intaglio surface should be re-etched after internal adjustment, or after refiring, is lacking. Purpose: The purpose of this in vitro study was to investigate the effects of different sequences of etching, refiring, diamond rotary instrument adjustment, airborne-particle abrasion, and re-etching on the microstructure and surface roughness of the intaglio surface of heat-pressed LDGCs. Material and methods: Heat-pressed LDGC specimens were ground with abrasive paper to produce a uniformly flat surface. The groups (n=3) were subjected to different combinations of etching, refiring, diamond rotary instrument adjustment, airborne-particle abrasion, and re-etching. X-ray diffraction was used to characterize the crystalline phases. Scanning electron microscopy and surface profilometry were used to characterize the microstructure and surface roughness. Results: Qualitative differences were observed in the surface texture of specimens etched for different periods. Excessive etching revealed more of the underlying lithium disilicate crystallites and caused surface pitting for the longest etching period studied. Refiring altered the surface condition but did not completely remove the texture created by the original etching. Diamond rotary instrument adjustment resulted in appreciable surface damage and a higher mean value of measured surface roughness (with or without re-etching) than the other groups. Airborne-particle abrasion caused embedding of particles in the specimen surface, likely corresponding to the abrasion media, although this process resulted in qualitatively less surface damage than diamond rotary instrument adjustment. Conclusions: Excessive etching, refiring, and adjustment by airborne-particle abrasion or diamond rotary instrument result in qualitative changes in surface condition. Adjustment by diamond rotary instrument results in appreciable surface damage.
AB - Statement of problem: Clinical adjustment of a lithium disilicate glass-ceramic (LDGC) restoration may necessitate its return to the laboratory for additional firing. Evidence of how the intaglio surface should be re-etched after internal adjustment, or after refiring, is lacking. Purpose: The purpose of this in vitro study was to investigate the effects of different sequences of etching, refiring, diamond rotary instrument adjustment, airborne-particle abrasion, and re-etching on the microstructure and surface roughness of the intaglio surface of heat-pressed LDGCs. Material and methods: Heat-pressed LDGC specimens were ground with abrasive paper to produce a uniformly flat surface. The groups (n=3) were subjected to different combinations of etching, refiring, diamond rotary instrument adjustment, airborne-particle abrasion, and re-etching. X-ray diffraction was used to characterize the crystalline phases. Scanning electron microscopy and surface profilometry were used to characterize the microstructure and surface roughness. Results: Qualitative differences were observed in the surface texture of specimens etched for different periods. Excessive etching revealed more of the underlying lithium disilicate crystallites and caused surface pitting for the longest etching period studied. Refiring altered the surface condition but did not completely remove the texture created by the original etching. Diamond rotary instrument adjustment resulted in appreciable surface damage and a higher mean value of measured surface roughness (with or without re-etching) than the other groups. Airborne-particle abrasion caused embedding of particles in the specimen surface, likely corresponding to the abrasion media, although this process resulted in qualitatively less surface damage than diamond rotary instrument adjustment. Conclusions: Excessive etching, refiring, and adjustment by airborne-particle abrasion or diamond rotary instrument result in qualitative changes in surface condition. Adjustment by diamond rotary instrument results in appreciable surface damage.
UR - http://www.scopus.com/inward/record.url?scp=85072329107&partnerID=8YFLogxK
U2 - 10.1016/j.prosdent.2019.06.010
DO - 10.1016/j.prosdent.2019.06.010
M3 - Article
C2 - 31547955
AN - SCOPUS:85072329107
SN - 0022-3913
VL - 122
SP - 411.e1-411.e10
JO - Journal of Prosthetic Dentistry
JF - Journal of Prosthetic Dentistry
IS - 4
ER -