TY - JOUR
T1 - Ambient lighting
T2 - effect of illumination on soft-copy viewing of radiographs of the wrist.
AU - Brennan, Patrick C.
AU - McEntee, Mark
AU - Evanoff, Michael
AU - Phillips, Peter
AU - O'Connor, William T.
AU - Manning, David J.
PY - 2007/2
Y1 - 2007/2
N2 - OBJECTIVE: The aim of the work was to establish optimum ambient light conditions for viewing radiologic images of the wrist on liquid crystal display monitors. MATERIALS AND METHODS: Five ambient light levels were investigated: 480, 100, 40, 25, and 7 lux. Seventy-nine experienced radiologists were asked to examine 30 posteroanterior wrist images and decide whether a fracture was present. All images were displayed on liquid crystal display monitors. Receiver operating characteristic analysis was performed, and the numbers of false-positive and false-negative findings were recorded. RESULTS: For all the radiologists, greater area under the receiver operating characteristic curve and lower numbers of false-positive and false-negative findings were recorded at 40 and 25 lux compared with 480 and 100 lux. At 7 lux, the results were generally similar to those at 480 and 100 lux. The experience and knowledge of radiologists specializing in imaging of musculoskeletal trauma appeared to compensate in part for inappropriate lighting levels. CONCLUSION: Typical office lighting and current recommendations on ambient lighting can reduce diagnostic efficacy compared with lower levels of ambient lighting. If, however, no light other than that of the monitor is used, results are similar to those with excessive levels of lighting. Careful control of ambient lighting is therefore required to ensure that diagnostic accuracy is maximized, particularly for clinicians not expert in interpreting posteroanterior wrist images.
AB - OBJECTIVE: The aim of the work was to establish optimum ambient light conditions for viewing radiologic images of the wrist on liquid crystal display monitors. MATERIALS AND METHODS: Five ambient light levels were investigated: 480, 100, 40, 25, and 7 lux. Seventy-nine experienced radiologists were asked to examine 30 posteroanterior wrist images and decide whether a fracture was present. All images were displayed on liquid crystal display monitors. Receiver operating characteristic analysis was performed, and the numbers of false-positive and false-negative findings were recorded. RESULTS: For all the radiologists, greater area under the receiver operating characteristic curve and lower numbers of false-positive and false-negative findings were recorded at 40 and 25 lux compared with 480 and 100 lux. At 7 lux, the results were generally similar to those at 480 and 100 lux. The experience and knowledge of radiologists specializing in imaging of musculoskeletal trauma appeared to compensate in part for inappropriate lighting levels. CONCLUSION: Typical office lighting and current recommendations on ambient lighting can reduce diagnostic efficacy compared with lower levels of ambient lighting. If, however, no light other than that of the monitor is used, results are similar to those with excessive levels of lighting. Careful control of ambient lighting is therefore required to ensure that diagnostic accuracy is maximized, particularly for clinicians not expert in interpreting posteroanterior wrist images.
UR - http://www.scopus.com/inward/record.url?scp=33847068882&partnerID=8YFLogxK
U2 - 10.2214/AJR.05.2048
DO - 10.2214/AJR.05.2048
M3 - Article
C2 - 17242225
AN - SCOPUS:33847068882
SN - 1546-3141
VL - 188
SP - W177-180
JO - AJR. American journal of roentgenology
JF - AJR. American journal of roentgenology
IS - 2
ER -