An Improved Single-Stage PFC AC-DC Power Supply

Research output: Contribution to journalArticlepeer-review

Abstract

This letter describes an enhancement to a previously reported single-stage transformer-leakage-inductance-based power-factor-corrected isolated power supply. An improved switch timing calculation algorithm is developed to achieve zero current switch on of the active rectifier switches. The algorithm is based on an analytical model of the system relating the gate timing to the input and output voltages and control inputs. Remarkably, a closed-form expression for the switch timing can be derived and used to calculate and apply the timings in real time without the need for high-speed measurements or resonant structures. A prototype 1.25 kW prototype power supply is implemented using the proposed technique and performance measurements presented.

Original languageEnglish
Article number8693578
Pages (from-to)8283-8288
Number of pages6
JournalIEEE Transactions on Power Electronics
Volume34
Issue number9
DOIs
Publication statusPublished - Sep 2019

Keywords

  • AC-DC power conversion
  • power factor correction
  • transformer leakage inductance
  • zero current switching

Fingerprint

Dive into the research topics of 'An Improved Single-Stage PFC AC-DC Power Supply'. Together they form a unique fingerprint.

Cite this