T1 - EFFECT OF SIZE ON SINGLE AND DOUBLE OPTICAL MICROBOTTLE RESONATOR HUMIDITY SENSORS
AU - Md Johari, Md Ashadi
AU - Abdul Khudus, Muhammad Imran Mustafa
AU - Bin Jali, Mohd Hafiz
AU - Al Noman, Abdullah
AU - Wadi Harun, Sulaiman
N1 - Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/12/1
Y1 - 2018/12/1
N2 - An experimental study on the effect of whispering gallery mode (WGMs) on micro-bottle resonator (MBR) and its application on humidity sensing is presented. Different transmission mode spectra observed when the diameter of MBR (Db) change from 130μm to 190μm. The Q-factor for single and double MBRs ware observed >104 for all cases. The size and number of MBRs effecting Q-factor value which are high Q-factor value for smallest size Db=130μm for single MBR and Pair-4 (combination of two biggest MBRs Db=190μm) for double MBRs. Application of single and double MBRs in humidity sensing received various sensing performance. With the highest sensitivity value, linearity >90% and P-value >10-13 make MBR with diameter 130μm to be the best performance as humidity sensor for all cases. Both single and double MBRs are stable over 60 seconds. Overall, the size of the MBR has been shown to be more important than the quantity of MBRs for humidity sensing. Indeed, double MBRs actually perform worse than single MBRs as humidity sensors.
AB - An experimental study on the effect of whispering gallery mode (WGMs) on micro-bottle resonator (MBR) and its application on humidity sensing is presented. Different transmission mode spectra observed when the diameter of MBR (Db) change from 130μm to 190μm. The Q-factor for single and double MBRs ware observed >104 for all cases. The size and number of MBRs effecting Q-factor value which are high Q-factor value for smallest size Db=130μm for single MBR and Pair-4 (combination of two biggest MBRs Db=190μm) for double MBRs. Application of single and double MBRs in humidity sensing received various sensing performance. With the highest sensitivity value, linearity >90% and P-value >10-13 make MBR with diameter 130μm to be the best performance as humidity sensor for all cases. Both single and double MBRs are stable over 60 seconds. Overall, the size of the MBR has been shown to be more important than the quantity of MBRs for humidity sensing. Indeed, double MBRs actually perform worse than single MBRs as humidity sensors.
UR - https://www.scopus.com/pages/publications/85056165150
U2 - 10.1016/j.sna.2018.10.035
DO - 10.1016/j.sna.2018.10.035
M3 - Article
AN - SCOPUS:85056165150
SN - 0924-4247
VL - 284
SP - 286
EP - 291
JO - Sensors and Actuators, A: Physical
JF - Sensors and Actuators, A: Physical
ER -