TY - JOUR
T1 - Experimental determination of circumferential properties of fresh carotid artery plaques
AU - Lawlor, Michael G.
AU - O'Donnell, Michael R.
AU - O'Connell, Barry M.
AU - Walsh, Michael T.
N1 - Copyright © 2011 Elsevier Ltd. All rights reserved.
PY - 2011/6/3
Y1 - 2011/6/3
N2 - Carotid endarterectomy (CEA) is currently accepted as the gold standard for interventional revascularisation of diseased arteries belonging to the carotid bifurcation. Despite the proven efficacy of CEA, great interest has been generated in carotid angioplasty and stenting (CAS) as an alternative to open surgical therapy. CAS is less invasive compared with CEA, and has the potential to successfully treat lesions close to the aortic arch or distal internal carotid artery (ICA). Following promising results from two recent trials (CREST; Carotid revascularisation endarterectomy versus stenting trial, and ICSS; International carotid stenting study) it is envisaged that there will be a greater uptake in carotid stenting, especially amongst the group who do not qualify for open surgical repair, thus creating pressure to develop computational models that describe a multitude of plaque models in the carotid arteries and their reaction to the deployment of such interventional devices. Pertinent analyses will require fresh human atherosclerotic plaque material characteristics for different disease types. This study analysed atherosclerotic plaque characteristics from 18 patients tested on site, post-surgical revascularisation through endarterectomy, with 4 tissue samples being excluded from tensile testing based on large width-length ratios. According to their mechanical behaviour, atherosclerotic plaques were separated into 3 grades of stiffness. Individual and group material coefficients were then generated analytically using the Yeoh strain energy function. The ultimate tensile strength (UTS) of each sample was also recorded, showing large variation across the 14 atherosclerotic samples tested. Experimental Green strains at rupture varied from 0.299 to 0.588 and the Cauchy stress observed in the experiments was between 0.131 and 0.779. MPa. It is expected that this data may be used in future design optimisation of next generation interventional medical devices for the treatment and revascularisation of diseased arteries of the carotid bifurcation.
AB - Carotid endarterectomy (CEA) is currently accepted as the gold standard for interventional revascularisation of diseased arteries belonging to the carotid bifurcation. Despite the proven efficacy of CEA, great interest has been generated in carotid angioplasty and stenting (CAS) as an alternative to open surgical therapy. CAS is less invasive compared with CEA, and has the potential to successfully treat lesions close to the aortic arch or distal internal carotid artery (ICA). Following promising results from two recent trials (CREST; Carotid revascularisation endarterectomy versus stenting trial, and ICSS; International carotid stenting study) it is envisaged that there will be a greater uptake in carotid stenting, especially amongst the group who do not qualify for open surgical repair, thus creating pressure to develop computational models that describe a multitude of plaque models in the carotid arteries and their reaction to the deployment of such interventional devices. Pertinent analyses will require fresh human atherosclerotic plaque material characteristics for different disease types. This study analysed atherosclerotic plaque characteristics from 18 patients tested on site, post-surgical revascularisation through endarterectomy, with 4 tissue samples being excluded from tensile testing based on large width-length ratios. According to their mechanical behaviour, atherosclerotic plaques were separated into 3 grades of stiffness. Individual and group material coefficients were then generated analytically using the Yeoh strain energy function. The ultimate tensile strength (UTS) of each sample was also recorded, showing large variation across the 14 atherosclerotic samples tested. Experimental Green strains at rupture varied from 0.299 to 0.588 and the Cauchy stress observed in the experiments was between 0.131 and 0.779. MPa. It is expected that this data may be used in future design optimisation of next generation interventional medical devices for the treatment and revascularisation of diseased arteries of the carotid bifurcation.
KW - Carotid atherosclerotic plaque
KW - Hyperelasticity
KW - Mechanical properties
KW - Plaque mechanics
UR - http://www.scopus.com/inward/record.url?scp=79956089597&partnerID=8YFLogxK
U2 - 10.1016/j.jbiomech.2011.03.033
DO - 10.1016/j.jbiomech.2011.03.033
M3 - Article
C2 - 21497353
AN - SCOPUS:79956089597
SN - 0021-9290
VL - 44
SP - 1709
EP - 1715
JO - Journal of Biomechanics
JF - Journal of Biomechanics
IS - 9
ER -