TY - GEN
T1 - Fabry-Pérot based refractive index optical fiber sensor for measurement of oxygen concentration levels in hypoxic tumors during radiotherapy treatment
AU - Viphavakit, Charusluk
AU - Duraibabu, Dineshbabu
AU - O'Keeffe, Sinead
AU - Lewis, Elfed
N1 - Publisher Copyright:
© 2017 SPIE.
PY - 2017
Y1 - 2017
N2 - An optical fiber sensor based on Fabry-Pérot interferometer to measure the refractive index changes due to oxygenation level changes in hypoxic tumors for radiotherapy treatments is proposed. The sensors have an outer diameter of 220μm with a 20-30μm length air-cavity and a 30μm thickness end cap located at the tip of the sensor. The sensors are used to measure the phase change in the received optical spectrum when there is a change in refractive index using a Fast Fourier Transform based analysis method. The refractive index change is measured in order to determine the oxygenation level in hypoxic tumors. In this paper, different concentrations of iso-propanol solution are prepared to produce refractive index values between 1.3438 and 1.3655 in order to mimic the refractive index of hemoglobin. The sensors are coated with a 100 nm thick gold layer and a comparison is made with non-coated sensors. The coated sensors have a resolution in order of 10-3 RIU.
AB - An optical fiber sensor based on Fabry-Pérot interferometer to measure the refractive index changes due to oxygenation level changes in hypoxic tumors for radiotherapy treatments is proposed. The sensors have an outer diameter of 220μm with a 20-30μm length air-cavity and a 30μm thickness end cap located at the tip of the sensor. The sensors are used to measure the phase change in the received optical spectrum when there is a change in refractive index using a Fast Fourier Transform based analysis method. The refractive index change is measured in order to determine the oxygenation level in hypoxic tumors. In this paper, different concentrations of iso-propanol solution are prepared to produce refractive index values between 1.3438 and 1.3655 in order to mimic the refractive index of hemoglobin. The sensors are coated with a 100 nm thick gold layer and a comparison is made with non-coated sensors. The coated sensors have a resolution in order of 10-3 RIU.
KW - Fabry-Pérot interferometer
KW - Hypoxic tumors
KW - Refractive index sensors
UR - http://www.scopus.com/inward/record.url?scp=85019126688&partnerID=8YFLogxK
U2 - 10.1117/12.2265084
DO - 10.1117/12.2265084
M3 - Conference contribution
AN - SCOPUS:85019126688
T3 - Proceedings of SPIE - The International Society for Optical Engineering
BT - 25th International Conference on Optical Fiber Sensors
A2 - Yuan, Libo
A2 - Chung, Youngjoo
A2 - Jin, Wei
A2 - Lee, Byoungho
A2 - Canning, John
A2 - Nakamura, Kentaro
PB - SPIE
T2 - 25th International Conference on Optical Fiber Sensors, OFS 2017
Y2 - 24 April 2017 through 28 April 2017
ER -