From chip to cooling tower data center modeling: Part II Influence of chip temperature control philosophy

Ed J. Walsh, Thomas J. Breen, J. Punch, Amip J. Shah, Cullen E. Bash

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

The chiller cooled data center environment consists of many interlinked elements that are usually treated as individual components. This chain of components and their influences on each other must be considered in determining the benefits of any data center design and operational strategies seeking to improve efficiency, such as temperature control fan algorithms. Using the models developed in part I of this work, this paper extends the analysis to include the electronics within the rack through considering the processor heat sink temperature. This has allowed determination of the influence of various cooling strategies on the data center coefficient of performance. The strategy of increasing inlet aisle temperature is examined in some detail and found not to be a robust methodology for improving the overall energy performance of the data center, while tight temperature controls at the chip level consistently provides better performance, yielding more computing per watt of cooling power. These findings are of strong practical relevance for the design of fan control algorithms at the rack level and general operational strategies in data centers. Finally, the impact of heat sink thermal resistance is considered and the potential data center efficiency gains from improved heat sink designs are discussed.

Original languageEnglish
Title of host publication2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010
DOIs
Publication statusPublished - 2010
Event2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010 - Las Vegas, NV, United States
Duration: 2 Jun 20105 Jun 2010

Publication series

Name2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010

Conference

Conference2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010
Country/TerritoryUnited States
CityLas Vegas, NV
Period2/06/105/06/10

Keywords

  • Chip to cooling tower
  • Data center cooling
  • Energy efficiency
  • Heat sink

Fingerprint

Dive into the research topics of 'From chip to cooling tower data center modeling: Part II Influence of chip temperature control philosophy'. Together they form a unique fingerprint.

Cite this