Abstract
The chiller cooled data center environment consists of many interlinked elements that are usually treated as individual components. This chain of components and their influences on each other must be considered in determining the benefits of any data center design and operational strategies seeking to improve efficiency, such as temperature control fan algorithms. Using the models developed in part I of this work, this paper extends the analysis to include the electronics within the rack through considering the processor heat sink temperature. This has allowed determination of the influence of various cooling strategies on the data center coefficient of performance. The strategy of increasing inlet aisle temperature is examined in some detail and found not to be a robust methodology for improving the overall energy performance of the data center, while tight temperature controls at the chip level consistently provides better performance, yielding more computing per watt of cooling power. These findings are of strong practical relevance for the design of fan control algorithms at the rack level and general operational strategies in data centers. Finally, the impact of heat sink thermal resistance is considered and the potential data center efficiency gains from improved heat sink designs are discussed.
| Original language | English |
|---|---|
| Title of host publication | 2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010 |
| DOIs | |
| Publication status | Published - 2010 |
| Event | 2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010 - Las Vegas, NV, United States Duration: 2 Jun 2010 → 5 Jun 2010 |
Publication series
| Name | 2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010 |
|---|
Conference
| Conference | 2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2010 |
|---|---|
| Country/Territory | United States |
| City | Las Vegas, NV |
| Period | 2/06/10 → 5/06/10 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Chip to cooling tower
- Data center cooling
- Energy efficiency
- Heat sink
Fingerprint
Dive into the research topics of 'From chip to cooling tower data center modeling: Part II Influence of chip temperature control philosophy'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver