TY - GEN
T1 - Influence of concentration and number of image pairs in μ-PIV experiments
AU - Chiavaroll, Stefano
AU - Newport, David
AU - Morini, Glan Luca
AU - Lattes, Christine Barrot
AU - Baldas, Lucien
AU - Colin, Stéphane
PY - 2007
Y1 - 2007
N2 - Micro Particle Image Velocimetry (μ-PIV) is a non-intrusive technique widely used nowadays to experimentally obtain the velocity Field of a micro flow. The main goal of this research was to examine the influence of particle concentration and the number of images acquired, on the accuracy of the μ-PIV velocity measurement. For this reason, a comparison between experimental and analytical values was made. It has been demonstrated that the influence of the seeding concentration on the accuracy of the velocity measurements, into the investigated range, can be considered insignificant. On the other hand, the number of images selected for the cross-correlation is more important for the accuracy of the measurements. By increasing the quantity of images processed it is possible to artificially increase the seeding concentration and reduce the scatter. However, this considerably increases the processing time for the experiment. A trade-off is required between obtaining a highly accurate result without losing precious experimental down time. When the range of the concentration is fixed, it is possible to set the maximum inaccuracy allowance tolerated for the experiment. There is a compromise between a better precision and adequate time to process the data.
AB - Micro Particle Image Velocimetry (μ-PIV) is a non-intrusive technique widely used nowadays to experimentally obtain the velocity Field of a micro flow. The main goal of this research was to examine the influence of particle concentration and the number of images acquired, on the accuracy of the μ-PIV velocity measurement. For this reason, a comparison between experimental and analytical values was made. It has been demonstrated that the influence of the seeding concentration on the accuracy of the velocity measurements, into the investigated range, can be considered insignificant. On the other hand, the number of images selected for the cross-correlation is more important for the accuracy of the measurements. By increasing the quantity of images processed it is possible to artificially increase the seeding concentration and reduce the scatter. However, this considerably increases the processing time for the experiment. A trade-off is required between obtaining a highly accurate result without losing precious experimental down time. When the range of the concentration is fixed, it is possible to set the maximum inaccuracy allowance tolerated for the experiment. There is a compromise between a better precision and adequate time to process the data.
UR - http://www.scopus.com/inward/record.url?scp=40449101255&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:40449101255
SN - 0791842886
SN - 9780791842881
T3 - 2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007
SP - 1
EP - 6
BT - 2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007
T2 - 2007 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007
Y2 - 30 July 2007 through 2 August 2007
ER -