TY - JOUR
T1 - Modelling and fixed bed column adsorption of Cr(VI) onto orthophosphoric acid-activated lignin
AU - Albadarin, Ahmad B.
AU - Mangwandi, Chirangano
AU - Al-Muhtaseb, Ala'A H.
AU - Walker, Gavin M.
AU - Allen, Stephen J.
AU - Ahmad, Mohammad N.M.
PY - 2012/6
Y1 - 2012/6
N2 - The advantage of using an available and abundant residual biomass, such as lignin, as a raw material for activated carbons is that it provides additional economical interest to the technical studies. In the current investigation, a more complete understanding of adsorption of Cr(VI) from aqueous systems onto H 3PO 4-acid activated lignin has been achieved via microcolumns, which were operated under various process conditions. The practice of using microcolumn is appropriate for defining the adsorption parameters and for screening a large number of potential adsorbents. The effects of solution pH (2-8), initial metal ion concentration (0.483-1.981 mmol·L -1), flow rate (1.0-3.1 cm 3·min -1), ionic strength (0.01-0.30 mmol·L -1) and adsorbent mass (0.11-0.465 g) on Cr(VI) adsorption were studied by assessing the microcolumn breakthrough curve. The microcolumn data were fitted by the Thomas model, the modified Dose model and the BDST model. As expected, the adsorption capacity increased with initial Cr(VI) concentration. High linear flow rates, pH values and ionic strength led to early breakthrough of Cr(VI). The model constants obtained in this study can be used for the design of pilot scale adsorption process.
AB - The advantage of using an available and abundant residual biomass, such as lignin, as a raw material for activated carbons is that it provides additional economical interest to the technical studies. In the current investigation, a more complete understanding of adsorption of Cr(VI) from aqueous systems onto H 3PO 4-acid activated lignin has been achieved via microcolumns, which were operated under various process conditions. The practice of using microcolumn is appropriate for defining the adsorption parameters and for screening a large number of potential adsorbents. The effects of solution pH (2-8), initial metal ion concentration (0.483-1.981 mmol·L -1), flow rate (1.0-3.1 cm 3·min -1), ionic strength (0.01-0.30 mmol·L -1) and adsorbent mass (0.11-0.465 g) on Cr(VI) adsorption were studied by assessing the microcolumn breakthrough curve. The microcolumn data were fitted by the Thomas model, the modified Dose model and the BDST model. As expected, the adsorption capacity increased with initial Cr(VI) concentration. High linear flow rates, pH values and ionic strength led to early breakthrough of Cr(VI). The model constants obtained in this study can be used for the design of pilot scale adsorption process.
KW - activated carbon
KW - adsorption
KW - fixed bed column
KW - hexavalent chromium
KW - lignin
UR - http://www.scopus.com/inward/record.url?scp=84864248058&partnerID=8YFLogxK
U2 - 10.1016/S1004-9541(11)60208-5
DO - 10.1016/S1004-9541(11)60208-5
M3 - Article
AN - SCOPUS:84864248058
SN - 1004-9541
VL - 20
SP - 469
EP - 477
JO - Chinese Journal of Chemical Engineering
JF - Chinese Journal of Chemical Engineering
IS - 3
ER -