TY - JOUR
T1 - Patient exposure dose in interventional cardiology per clinical and technical complexity levels. Part 1
T2 - results of the VERIDIC project
AU - Feghali, Joelle Ann
AU - Delépierre, Julie
AU - Belac, Olivera Ciraj
AU - Dabin, Jérémie
AU - Deleu, Marine
AU - De Monte, Francesca
AU - Dobric, Milan
AU - Gallagher, Aoife
AU - Hadid-Beurrier, Lama
AU - Henry, Patrick
AU - Hršak, Hrvoje
AU - Kiernan, Tom
AU - Kumar, Rajesh
AU - Knežević, Željka
AU - Maccia, Carlo
AU - Majer, Marija
AU - Malchair, Françoise
AU - Noble, Stéphane
AU - Obrad, Davor
AU - Sans Merce, Marta
AU - Sideris, Georgios
AU - Simantirakis, George
AU - Spaulding, Christian
AU - Tarantini, Giuseppe
AU - Van Ngoc Ty, Claire
N1 - Publisher Copyright:
© The Foundation Acta Radiologica 2021.
PY - 2023/1
Y1 - 2023/1
N2 - Background: Patients can be exposed to high skin doses during complex interventional cardiology (IC) procedures. Purpose: To identify which clinical and technical parameters affect patient exposure and peak skin dose (PSD) and to establish dose reference levels (DRL) per clinical complexity level in IC procedures. Material and Methods: Validation and Estimation of Radiation skin Dose in Interventional Cardiology (VERIDIC) project analyzed prospectively collected patient data from eight European countries and 12 hospitals where percutaneous coronary intervention (PCI), chronic total occlusion PCI (CTO), and transcatheter aortic valve implantation (TAVI) procedures were performed. A total of 62 clinical complexity parameters and 31 technical parameters were collected, univariate regressions were performed to identify those parameters affecting patient exposure and define DRL accordingly. Results: Patient exposure as well as clinical and technical parameters were collected for a total of 534 PCI, 219 CTO, and 209 TAVI. For PCI procedures, body mass index (BMI), number of stents ≥2, and total stent length >28 mm were the most prominent clinical parameters, which increased the PSD value. For CTO, these were total stent length >57 mm, BMI, and previous anterograde or retrograde technique that failed in the same session. For TAVI, these were male sex, BMI, and number of diseased vessels. DRL values for Kerma-area product (PKA), air kerma at patient entrance reference point (Ka,r), fluoroscopy time (FT), and PSD were stratified, respectively, for 14 clinical parameters in PCI, 10 in CTO, and four in TAVI. Conclusion: Prior knowledge of the key factors influencing the PSD will help optimize patient radiation protection in IC.
AB - Background: Patients can be exposed to high skin doses during complex interventional cardiology (IC) procedures. Purpose: To identify which clinical and technical parameters affect patient exposure and peak skin dose (PSD) and to establish dose reference levels (DRL) per clinical complexity level in IC procedures. Material and Methods: Validation and Estimation of Radiation skin Dose in Interventional Cardiology (VERIDIC) project analyzed prospectively collected patient data from eight European countries and 12 hospitals where percutaneous coronary intervention (PCI), chronic total occlusion PCI (CTO), and transcatheter aortic valve implantation (TAVI) procedures were performed. A total of 62 clinical complexity parameters and 31 technical parameters were collected, univariate regressions were performed to identify those parameters affecting patient exposure and define DRL accordingly. Results: Patient exposure as well as clinical and technical parameters were collected for a total of 534 PCI, 219 CTO, and 209 TAVI. For PCI procedures, body mass index (BMI), number of stents ≥2, and total stent length >28 mm were the most prominent clinical parameters, which increased the PSD value. For CTO, these were total stent length >57 mm, BMI, and previous anterograde or retrograde technique that failed in the same session. For TAVI, these were male sex, BMI, and number of diseased vessels. DRL values for Kerma-area product (PKA), air kerma at patient entrance reference point (Ka,r), fluoroscopy time (FT), and PSD were stratified, respectively, for 14 clinical parameters in PCI, 10 in CTO, and four in TAVI. Conclusion: Prior knowledge of the key factors influencing the PSD will help optimize patient radiation protection in IC.
KW - diagnostic reference levels
KW - Interventional cardiology
KW - peak skin dose
KW - VERIDIC
UR - http://www.scopus.com/inward/record.url?scp=85122106032&partnerID=8YFLogxK
U2 - 10.1177/02841851211061438
DO - 10.1177/02841851211061438
M3 - Article
C2 - 34958271
AN - SCOPUS:85122106032
SN - 0284-1851
VL - 64
SP - 108
EP - 118
JO - Acta Radiologica
JF - Acta Radiologica
IS - 1
ER -