TY - JOUR
T1 - Reliability and validity of an indoor local positioning system for measuring external load in ice hockey players
AU - Gamble, Alexander
N1 - Publisher Copyright:
© 2022 European College of Sport Science.
PY - 2023
Y1 - 2023
N2 - This study determined the reliability and validity of a Kinexon local positioning system (LPS) for measuring external load in ice hockey players during an on-ice session. Fourteen ice hockey players (25.1 y, 78.6 kg, 176.9 cm) wore two LPS sensors to examine the inter-sensor reliability of the LPS during an on-ice session, and LPS speed and acceleration were measured during 40 m linear on-ice sprints and compared to a previously validated robotic sprint device to examine LPS accuracy. The coefficient of variation (CV), standard error of measurement (SEM), and intra-class correlation coefficient (ICC) were calculated for each LPS measure. Pearson’s correlations, simple linear regressions, and Bland–Altman plots were used to test the agreement and relationship between the two systems. Statistical significance was determined at p < 0.05. The majority of LPS measures were reliable (CV < 10% and ICC > 0.9) when comparing the two sensors worn by each player. Peak speed, speed at 5 m, and 0-5 m acceleration were all comparable to those reported by the robotic sprint device, with nearly perfect (peak speed and 0–5 m acceleration) and very large (speed at 5 m) magnitudes of correlation and mean biases <0.5 km/hr for speed measures and <0.01 m/s
2 for acceleration. The present results demonstrate that the Kinexon LPS is reliable and accurate for investigating on-ice external load in ice hockey players when sensors are consistently secured on the back of the players’ shoulder pads.
AB - This study determined the reliability and validity of a Kinexon local positioning system (LPS) for measuring external load in ice hockey players during an on-ice session. Fourteen ice hockey players (25.1 y, 78.6 kg, 176.9 cm) wore two LPS sensors to examine the inter-sensor reliability of the LPS during an on-ice session, and LPS speed and acceleration were measured during 40 m linear on-ice sprints and compared to a previously validated robotic sprint device to examine LPS accuracy. The coefficient of variation (CV), standard error of measurement (SEM), and intra-class correlation coefficient (ICC) were calculated for each LPS measure. Pearson’s correlations, simple linear regressions, and Bland–Altman plots were used to test the agreement and relationship between the two systems. Statistical significance was determined at p < 0.05. The majority of LPS measures were reliable (CV < 10% and ICC > 0.9) when comparing the two sensors worn by each player. Peak speed, speed at 5 m, and 0-5 m acceleration were all comparable to those reported by the robotic sprint device, with nearly perfect (peak speed and 0–5 m acceleration) and very large (speed at 5 m) magnitudes of correlation and mean biases <0.5 km/hr for speed measures and <0.01 m/s
2 for acceleration. The present results demonstrate that the Kinexon LPS is reliable and accurate for investigating on-ice external load in ice hockey players when sensors are consistently secured on the back of the players’ shoulder pads.
U2 - 10.1080/17461391.2022.2032371
DO - 10.1080/17461391.2022.2032371
M3 - Article
SN - 1746-1391
VL - 23
SP - -
JO - European Journal of Sport Science
JF - European Journal of Sport Science
IS - 3
ER -