Warmed contrast media temperature loss in traditional manifold systems during angiographic procedures

Kevin J. O'Sullivan, Tjaša Kermavnar, Kenneth A. Gorski, Samer Arnous, Leonard W. O'Sullivan

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Extrinsic warming of contrast media (CM) to 37 °C before angiographic procedures is performed to improve bolus kinetics and avoid potential adverse effects. Extrinsically warmed CM readily loses temperature after removal from the warming cabinet, but the extent of its cooling has not been previously investigated. Purpose: To assess temperature loss of extrinsically warmed CM in tubing of traditional angiographic manifolds during simulated angiography. Material and Methods: In total, 35 scheduled diagnostic angiographic procedures were observed in a hospital setting. Relevant time points of CM use during the procedures were recorded. The shortest, median, and longest procedures were then simulated in the experimental laboratory to measure CM temperatures at specific times at three locations along the tubing system. Results: The angiographic procedures lasted 7.0–26.6 min (median = 11.7 min), with the total duration dependent primarily on the time from contrast being removed from the warming cabinet to the commencement of imaging. During the simulated procedures, consistent patterns of temperature loss were observed. By the last simulated angiographic run, injected CM temperature decreased by 7.4–16.4 °C, depending on procedure length. Most of the heat loss occurred in the tubing between the CM bottle and coronary control syringe. Conclusion: During angiographic procedures, prewarmed CM loses its temperature rapidly with the duration of exposure to ambient room temperature. If no additional measures are employed to maintain its temperature outside of the warming cabinet, extrinsic warming has limited impact on injected CM temperature.

Original languageEnglish
Pages (from-to)1627-1633
Number of pages7
JournalActa Radiologica
Volume63
Issue number12
DOIs
Publication statusPublished - Dec 2022

Keywords

  • angiography
  • Cardiac
  • contrast agents – other

Fingerprint

Dive into the research topics of 'Warmed contrast media temperature loss in traditional manifold systems during angiographic procedures'. Together they form a unique fingerprint.

Cite this